Browsing by Author "Santos, F. P."
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Publication Accurate γ and mev-electron track reconstruction with an ultra-low diffusion xenon/tma tpc at 10 atm(Elsevier, 2015-12-21) Gonzalez-Diaz, Diego; Alvarez, V.; Borges, F. I. G.; Camargo, M.; Carcel, S.; Cebrian, S.; Cervera, A.; Conde, C. A. N.; Dafni, T.; Diaz, J.; Esteve, R.; Fernandes, L. M. P.; Ferrari, P.; Ferreira, A. L.; Freitas, E. D. C.; Gehmani, V. M.; Goldschmidt, A.; Gomez-Cadenas, J. J.; Gutierrez, R. M.; Hauptman, J.; Hernando Morata, J. A.; Herrera, D. C.; Irastorza, I. G.; Labarga, L.; Laing, A.; Liubarsky, I.; Lopez-March, N.; Lorca, D.; Losada, M.; Luzon, G.; Mari, A.; Martin-Albo, J.; Martinez-Lema, G.; Martinez, A.; Miller, T.; Monrabal, F.; Monserrate, M.; Monteiro, C. M. B.; Mora, F. J.; Moutinho, L. M.; Munoz Vidal, J.; Nebot-Guinot, M.; Nygren, D.; Oliveira, C. A. B.; Perez, J.; Perez Aparicio, J. L.; Querol, M.; Renner, J.; Ripoll, L.; Rodriguez, J.; Santos, F. P.; dos Santos, J. M. F.; Serra, L.; Shuman, D.; Simon, A.; Sofka, C.; Sorel, M.; Toledo, J. F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J. F. C. A.; Villar, J. A.; Webb, R.; White, J. T.; Yahlali, N.; Azevedo, C.; Aznarab, F.; Calvet, D.; Castel, J.; Ferrer-Ribas, E.; Garcia, J. A.; Giomataris, I.; Gomez, H.; Iguaz, F. J.; Lagraba, A.; Le Coguie, A.; Mols, J. P.; Rodriguez, A.; Ruiz-Choliz, E.; Segui, L.; Tomas, A.; Veenhof, R.; Şahin, Özkan; ŞAHİN, ÖZKAN; Bursa Uludağ Üniversitesi/Fen Edebiyat Fakültesi; I-9715-2017We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in similar to 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +/- 0.13 mm-sigma (longitudinal), 0.95 +/- 0.20 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8 mm x 8 mm x 1.2 mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (epsilon) at full width half maximum (R) inside the fiducial volume ranged from R = 14.6% (30 keV) to R = 4.6% (1.275 MeV).This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (beta beta 0 nu) in Xe-136, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R =1.4%root MeV/epsilon levels obtained in small sensors are discussed.Item Experimental ion mobility measurements in Ar-N2(IOP Publishing Ltd, 2018-10-12) Santos, M. A.G.; Cortez, André F.V.; Perdigoto, J. M.C.; Escada, J.; Neves, P. N. B.; Santos, F. P.; Conde, C. A. N.; Borges, F. I. G. M.; Veenhof, Robert J.; Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü.; 6603742499Data on ion mobility is important to improve the performance of large volume gaseous detectors, since the detector signal can be influenced by the drift of the ions, namely in the cases where charge multiplication is used, for example in Multi-Wire Proportional Chambers (MWPCs) and in some Time Projection Chambers (TPCs). In the present work the results for the ion mobility measurements in Ar-N-2 mixtures are presented, using an experimental setup and method already tested in previous work. The results for this mixture show the presence of only one peak for all gas ratios of Ar-N-2, for reduced electric fields, E/N, in the range of 10-25 Td (2.4-6.1 kV.cm(-1).bar(-1)), and 8 Torr (10.6 mbar) pressure, at room temperature.