Volümetrik ark tedavi (VMAT) tekniği kullanarak tüm vücut ışınlaması ve tüm kemik iliği ışınlamasının dozimetrik karşılaştırılması

dc.contributor.authorYeşil, Abdullah
dc.contributor.buuauthorÖzbek, Tülay
dc.contributor.buuauthorAbakay, Candan Demiröz
dc.contributor.buuauthorKurt, Meral
dc.contributor.buuauthorÇetintaş, Sibel Kahraman
dc.contributor.buuauthorAltay, Ali
dc.contributor.buuauthorKahraman, Arda
dc.contributor.buuauthorSarıbaş, Öznur
dc.contributor.departmentBursa Uludağ Üniversitesi/Tıp Fakültesi/Radyasyon Onkolojisi Anabilim Dalı.tr_TR
dc.contributor.orcid0000-0001-5959-880Xtr_TR
dc.contributor.orcid0000-0001-5380-5898tr_TR
dc.contributor.orcid0000-0003-1637-910Xtr_TR
dc.contributor.orcid0000-0002-4483-9284tr_TR
dc.contributor.orcid0000-0003-2224-9248tr_TR
dc.contributor.orcid0000-0003-0150-8052tr_TR
dc.contributor.orcid0000-0003-4165-7028tr_TR
dc.date.accessioned2023-03-06T07:27:50Z
dc.date.available2023-03-06T07:27:50Z
dc.date.issued2022-09-12
dc.description.abstractBu araştırmada tüm vücut ışınlaması (TVI) ve tüm kemik iliği ışınlaması (TKI) için, Volümetrik Ark Tedavi (VMAT) tekniği kullanılarak, hedef hacim ve kritik organ dozlarının karşılaştırılması amaçlanmıştır. Çalışmada, insan doku ve organ yoğunluklarına sahip, rando fantom kullanıldı. VMAT planları günlük fraksiyon dozu 6 Gy olmak üzere toplam doz 12 Gy olacak şekilde, oluşturuldu. Hedef hacimler ve risk altındaki organların (RAO) aldığı doz değerleri karşılaştırıldı. VMAT-TVI için ortalama akciğer dozu, 7.6 Gy ve lens dozu 4.4 Gy iken, VMAT-TKI için, RAO’nun dozları 2.7 ila 7.15 Gy aralığındadır. Ayrıca her iki plan için tedavi öncesi kalite kontrolü Octavius 4D fantom kullanılarak, planlanan ve verilen dozlar arasında doz doğruluğu, her 3 düzlemde 3mm ve %3 kriterleri ile gama indeks analizi, her iki tedavi planı için ≤1 olduğu saptanmıştır. Planlanan ve uygulanan tedavi arasında oldukça hassas doz dağılımı olduğu gözlemlendi. Her iki tedavi tekniğinde de hedef volüm istenilen dozu aldığı, fakat VMAT-TVI tekniğinde, doz homojenliği ve tedavi uygulama tekniklerinin iyileştirilmesi gerektiği sonucuna varıldı. TKI ile akciğer dışındaki diğer RAO'ların da daha iyi korunabildiği saptandı. Çalışmamızın sonucunda, VMAT'ın gelecekte geleneksel tekniklere göre hem TVI hem de TKI uygulaması için uygun bir teknik olabileceği görüşüne varıldı.tr_TR
dc.description.abstractIt is aimed to compare target volume and critical organ doses using Volumeric arc therapy (VMAT) technique for Whole body irradiation (TVI) and Whole bone marrow irradiation (TKI). In the study, a random phantom with human tissue and organ densities was used.. VMAT plans were created with a daily fraction dose of 6 Gy and a total dose of 12 Gy. Target volumes and dose values received by critical organs were compared. Treatment plans The mean lung dose for VMAT-TVI is 7.6 Gy and the lens dose is 4.4 Gy, while organs at risk (OAR) doses for VMAT-TKI range from 2.7 to 7.15 Gy. In addition, pre-treatment quality control for both plans, dose accuracy between planned and administered doses using the Octavius 4D phantom, gamma index analysis with 3mm and 3% criteria in all 3 planes, we found that ≤1 for both treatment plans. We observed a very precise dose distribution between the planned and administered treatment. It was concluded that in both treatment techniques, the target volume received the desired dose, but in the VMAT-TBI technique, dose homogeneity and treatment application techniques should be improved. It was determined that other RAOs other than the lung were also better protected with TMI. As a result of our study, it was concluded that VMAT may be a suitable technique for both TBI and TMI application compared to traditional techniques in the future.en_US
dc.identifier.citationÖzbek, T. vd. (2022). ''Volümetrik ark tedavi (VMAT) tekniği kullanarak tüm vücut ışınlaması ve tüm kemik iliği ışınlamasının dozimetrik karşılaştırılması''. Uludağ Üniversitesi Tıp Fakültesi Dergisi, 48(3), 271-277.tr_TR
dc.identifier.endpage277tr_TR
dc.identifier.issn1300-414X
dc.identifier.issue3tr_TR
dc.identifier.startpage271tr_TR
dc.identifier.urihttps://doi.org/10.32708/uutfd.1149002
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/2558399
dc.identifier.urihttp://hdl.handle.net/11452/31354
dc.identifier.volume48tr_TR
dc.language.isotrtr_TR
dc.publisherBursa Uludağ Üniversitesitr_TR
dc.relation.collaborationSanayitr_TR
dc.relation.journalUludağ Üniversitesi Tıp Fakültesi Dergisi / Journal of Uludag University Medical Facultytr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectTüm vücut ışınlaması (TVI)tr_TR
dc.subjectToplam kemik iliği ışınlaması (TKI)tr_TR
dc.subjectVolümerik ark tedavisi (VMAT)tr_TR
dc.subjectKalite güvencesi (KG)tr_TR
dc.subjectTotal body irradiation (TBI)en_US
dc.subjectTotal marrow irradiation (TMI)en_US
dc.subjectVolumetric arc therapy (VMAT)en_US
dc.subjectQuality assurance (QA)en_US
dc.titleVolümetrik ark tedavi (VMAT) tekniği kullanarak tüm vücut ışınlaması ve tüm kemik iliği ışınlamasının dozimetrik karşılaştırılmasıtr_TR
dc.title.alternativeDosimetric comparison of total body irradiation and total marrow irradiation using volumetric arc therapy (VMAT)en_US
dc.typeArticleen_US
dc.typeAraştırma makalesitr_TR

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
48_3_1.pdf
Size:
628.93 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: