Toraks yerşimli özofagus kanseri tanılı olgularda 3 boyutlu konformal radyoterapi (3bkrt) ve hacimsel ayarlı ark terapi (VMAT) tekniğinin dozimetrik karşılaştırması: Retrospektif çalışma

dc.contributor.buuauthorAltaş, Habibe
dc.contributor.buuauthorKurt, Meral
dc.contributor.buuauthorTunç, Sema Gözcü
dc.contributor.buuauthorÇetintaş, Sibel Kahraman
dc.contributor.buuauthorAbakay, Candan Demiröz
dc.contributor.buuauthorİbicioğlu, Burcu
dc.contributor.buuauthorCura, Ece Ayfer
dc.contributor.buuauthorTuran, Abdulhamit
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentRadyasyon Onkolojisi Ana Bilim Dalı
dc.date.accessioned2021-04-07T11:45:16Z
dc.date.available2021-04-07T11:45:16Z
dc.date.issued2018-07-16
dc.description.abstractBu çalışmanın amacı; özofagus kanserinin radyoterapi ile tedavisinde kullanılan üç Boyutlu Konformal Radyoterapi (3BKRT) ve Hacimsel Ayarlı Ark Terapi (VMAT) tekniklerinin, hedef hacmi sararken riskli organları korumadaki etkilerini görmek ve kendi verilerini elde etmek; elde ettiğimiz bu retrospektif dozimetrik sonuçları birbirleriyle karşılaştırmaktır. Bu çalışma için; 10 küratif radyoterapi ile tedavi edilen toraks yerleşimli özofagus kanseri tanılı hasta seçildi. Fraksiyon dozu 1,8 Gy ve toplam doz 54 Gy olacak şekilde planlar hazırlandı. İki teknik arasında kritik organ dozu (OAR), Konformite İndeksi (CI) ve Homojenite İndeksi (HI) karşılaştırıldı. Yapılan istatistiksel karşılaştırma sonucunda PTV54’e ait değerlerin analizinde 3BKRT ve VMAT arasında sadece CI değerinde anlamlı fark görülmüştür (p=0,002). Akciğerin V5 ve V10 incelendiğinde en düşük değer 3BKRT tekniğinde görülmüştür (sırasıyla p=0,005, p=0,013). Kalbin en düşük V40 değeri ise VMAT tekniğinde elde edilmiştir (p=0,002). Ayrıca, Spinal kord Dmax değeri için bakıldığında VMAT tekniği 3BKRT’ye göre düşük değerlere sahiptir (p=0,001). Çalışmamızın sonucunda doz homojenliği ve riskli organlar açısından her iki teknikte kullanılabilir görülmesine rağmen ileri yaştaki bu hastalarda etki eden komorbiditeler göz önüne alındığında VMAT tekniği kullanımının tercih olabileceği görülmüştür.tr_TR
dc.description.abstractThe purpose of this study is; to see the effects of protecting critical organs while achieved target volume of three dimensional conformal Radiotherapy (3DCRT) and Volumetric Modulated Arc Therapy (VMAT) techniques that is used in radiotherapy treatment of esophageal cancer and obtain their own data; to compare these retrospective dosimetric results which is obtained to each. For this study, 10 patients that was treated curative radiotherapy in cases of diagnosed thoracic esophageal cancer were selected. Plans were prepared in terms of the fraction dose would be 1,8 Gy and totally 54 Gy. Critical organs, Conformity Index (CI) and Homogenity Index (HI) were compared between two techniques. As a results of dosimetric comparison showed no statistical difference for only CI value between 3DCRT and VMAT, when the analysis of values PTV54 (p=0,002). The values of the lung V5 and V10 analyzed, was seen the lowest values in 3BKRT technique (p=0,005 and p=0,013, respectively). The lowest V40 value of the heart was obtained with VMAT technique (p=0,002). Additionally, for the Dmax value of Spinal Cord, VMAT technique has lower values than 3DCRT (p=0,001). As results of our study, although both techniques could be seemed to be able to use in terms of dose homogenity and risk of organs, The VMAT techniques should be prefered to use with consider of comorbidities affecting these older patients.en_US
dc.identifier.citationAltaş, H. vd. (2018). ''Toraks yerşimli özofagus kanseri tanılı olgularda 3 boyutlu konformal radyoterapi (3bkrt) ve hacimsel ayarlı ark terapi (VMAT) tekniğinin dozimetrik karşılaştırması: Retrospektif çalışma''. Uludağ Üniversitesi Tıp Fakültesi Dergisi, 44(2), 117-124.tr_TR
dc.identifier.endpage124tr_TR
dc.identifier.issn1300-414X
dc.identifier.issue2tr_TR
dc.identifier.startpage117tr_TR
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/533596
dc.identifier.urihttp://hdl.handle.net/11452/19167
dc.identifier.volume44tr_TR
dc.language.isotrtr_TR
dc.publisherUludağ Üniversitesitr_TR
dc.relation.journalUludağ Üniversitesi Tıp Fakültesi Dergisi / Journal of Uludag University Medical Facultytr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectÖzofagus kanseritr_TR
dc.subjectRadyoterapitr_TR
dc.subject3BKRTtr_TR
dc.subjectVMATtr_TR
dc.subjectRadiotherapyen_US
dc.subjectEsophageal canceren_US
dc.subject3DCRTen_US
dc.titleToraks yerşimli özofagus kanseri tanılı olgularda 3 boyutlu konformal radyoterapi (3bkrt) ve hacimsel ayarlı ark terapi (VMAT) tekniğinin dozimetrik karşılaştırması: Retrospektif çalışmatr_TR
dc.title.alternativeDosimetric comparison of 3 dimensional conformal radiotherapy (3dcrt) and volumetric modulated arc therapy (VMAT) technique in cases of diagnosed thoracic esophageal cancer patients: A retrospective studyen_US
dc.typeArticleen_US
dc.typeAraştırma makalesitr_TR
local.contributor.departmentTıp Fakültesi/Radyasyon Onkolojisi Ana Bilim Dalıtr_TR

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
44_2_9.pdf
Size:
334.39 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: