Publication:
Rare use of Atrieve Vascular Snare™ for percutaneous transcatheter retrieval of central venous port catheter fragments

dc.contributor.authorNas, O. F.
dc.contributor.authorKaçar, E.
dc.contributor.authorDoğan, N.
dc.contributor.authorAtasoy, M. M.
dc.contributor.authorErdoğan, C.
dc.contributor.buuauthorNAS, ÖMER FATİH
dc.contributor.buuauthorErdoğan, Cüneyt
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentRadyoloji Ana Bilim Dalı
dc.contributor.researcheridAAG-8561-2021
dc.contributor.researcheridCOE-1124-2022
dc.date.accessioned2024-08-05T08:35:51Z
dc.date.available2024-08-05T08:35:51Z
dc.date.issued2015-11-01
dc.description.abstractCentral venous port catheters and peripherally inserted central catheters (PICC lines) are implanted in the central venous system usually for administration of chemotherapeutic agents and parenteral nutrition [1,2]. Long-term use of these catheters may cause such complications as occlusion, thrombosis, infection, fracture and intravascular dislocation of the catheter [2,3]. The incidence of intravascular dislocation of port catheters is rare( 0-3.1%) [1,3]. Fragments of a fractured port catheter might migrate towards the heart or pulmonary artery and cause embolization in the distal region of the organ resulting in mortality [1,4]. Therefore, port catheter fragments must be retrieved as soon as possible[ 1]. Percutaneous retrieval, removal by open thoracotomy and long-term anticoagulant therapy are the treatment options for fractured port catheters. Among these options, percutaneous transcatheter retrieval is usually a safe and effective method [1,5]. In this study, we report the retrieval of port catheter fragments extending from the superior vena cava to the right cardiac cavities using a three-loop 6F 12-20 mm snare( Atrieve Vascular Snare (TM); Angiotech, Gainesville, FL, United States) in two patients who complained of chest pain.
dc.identifier.doi10.1016/j.diii.2015.03.007
dc.identifier.endpage1230
dc.identifier.issn2211-5684
dc.identifier.issue11
dc.identifier.startpage1227
dc.identifier.urihttps://doi.org/10.1016/j.diii.2015.03.007
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S221156841500131X
dc.identifier.urihttps://hdl.handle.net/11452/43700
dc.identifier.volume96
dc.identifier.wos000363278900021
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherElsevier Masson
dc.relation.journalDiagnostic and Interventional Imaging
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCentral venous portcatheter
dc.subjectPercutaneous transcatheter
dc.subjectAtrieve vascular snare (tm)
dc.subjectRadiology, nuclear medicine & medical imaging
dc.titleRare use of Atrieve Vascular Snare™ for percutaneous transcatheter retrieval of central venous port catheter fragments
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Radyoloji Ana Bilim Dalı
relation.isAuthorOfPublication2aa7fdf5-f110-441f-b7ea-0d829a69f47b
relation.isAuthorOfPublication.latestForDiscovery2aa7fdf5-f110-441f-b7ea-0d829a69f47b

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nas_vd_2015.pdf
Size:
625.92 KB
Format:
Adobe Portable Document Format