Timing performance of a micro-channel-plate photomultiplier tube

Research Projects

Organizational Units

Journal Issue

Abstract

The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r<5.5 mm) the time resolution of the two MCP-PMTS combined is better than 10 ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTS as t(0) reference detectors has been validated.

Description

Keywords

Resolution, Mcp-pmt, Time resolution, Cherenkov light, Beam test, T0-reference, Monte-carlo simulation, Science & technology, Technology, Physical sciences, Instruments & instrumentation, Nuclear science & technology, Physics, nuclear, Physics, particles & fields, Instruments & instrumentation, Nuclear science & technology, Physics