Publication: Accurate γ and mev-electron track reconstruction with an ultra-low diffusion xenon/tma tpc at 10 atm
dc.contributor.author | Gonzalez-Diaz, Diego | |
dc.contributor.author | Alvarez, V. | |
dc.contributor.author | Borges, F. I. G. | |
dc.contributor.author | Camargo, M. | |
dc.contributor.author | Carcel, S. | |
dc.contributor.author | Cebrian, S. | |
dc.contributor.author | Cervera, A. | |
dc.contributor.author | Conde, C. A. N. | |
dc.contributor.author | Dafni, T. | |
dc.contributor.author | Diaz, J. | |
dc.contributor.author | Esteve, R. | |
dc.contributor.author | Fernandes, L. M. P. | |
dc.contributor.author | Ferrari, P. | |
dc.contributor.author | Ferreira, A. L. | |
dc.contributor.author | Freitas, E. D. C. | |
dc.contributor.author | Gehmani, V. M. | |
dc.contributor.author | Goldschmidt, A. | |
dc.contributor.author | Gomez-Cadenas, J. J. | |
dc.contributor.author | Gutierrez, R. M. | |
dc.contributor.author | Hauptman, J. | |
dc.contributor.author | Hernando Morata, J. A. | |
dc.contributor.author | Herrera, D. C. | |
dc.contributor.author | Irastorza, I. G. | |
dc.contributor.author | Labarga, L. | |
dc.contributor.author | Laing, A. | |
dc.contributor.author | Liubarsky, I. | |
dc.contributor.author | Lopez-March, N. | |
dc.contributor.author | Lorca, D. | |
dc.contributor.author | Losada, M. | |
dc.contributor.author | Luzon, G. | |
dc.contributor.author | Mari, A. | |
dc.contributor.author | Martin-Albo, J. | |
dc.contributor.author | Martinez-Lema, G. | |
dc.contributor.author | Martinez, A. | |
dc.contributor.author | Miller, T. | |
dc.contributor.author | Monrabal, F. | |
dc.contributor.author | Monserrate, M. | |
dc.contributor.author | Monteiro, C. M. B. | |
dc.contributor.author | Mora, F. J. | |
dc.contributor.author | Moutinho, L. M. | |
dc.contributor.author | Munoz Vidal, J. | |
dc.contributor.author | Nebot-Guinot, M. | |
dc.contributor.author | Nygren, D. | |
dc.contributor.author | Oliveira, C. A. B. | |
dc.contributor.author | Perez, J. | |
dc.contributor.author | Perez Aparicio, J. L. | |
dc.contributor.author | Querol, M. | |
dc.contributor.author | Renner, J. | |
dc.contributor.author | Ripoll, L. | |
dc.contributor.author | Rodriguez, J. | |
dc.contributor.author | Santos, F. P. | |
dc.contributor.author | dos Santos, J. M. F. | |
dc.contributor.author | Serra, L. | |
dc.contributor.author | Shuman, D. | |
dc.contributor.author | Simon, A. | |
dc.contributor.author | Sofka, C. | |
dc.contributor.author | Sorel, M. | |
dc.contributor.author | Toledo, J. F. | |
dc.contributor.author | Torrent, J. | |
dc.contributor.author | Tsamalaidze, Z. | |
dc.contributor.author | Veloso, J. F. C. A. | |
dc.contributor.author | Villar, J. A. | |
dc.contributor.author | Webb, R. | |
dc.contributor.author | White, J. T. | |
dc.contributor.author | Yahlali, N. | |
dc.contributor.author | Azevedo, C. | |
dc.contributor.author | Aznarab, F. | |
dc.contributor.author | Calvet, D. | |
dc.contributor.author | Castel, J. | |
dc.contributor.author | Ferrer-Ribas, E. | |
dc.contributor.author | Garcia, J. A. | |
dc.contributor.author | Giomataris, I. | |
dc.contributor.author | Gomez, H. | |
dc.contributor.author | Iguaz, F. J. | |
dc.contributor.author | Lagraba, A. | |
dc.contributor.author | Le Coguie, A. | |
dc.contributor.author | Mols, J. P. | |
dc.contributor.author | Rodriguez, A. | |
dc.contributor.author | Ruiz-Choliz, E. | |
dc.contributor.author | Segui, L. | |
dc.contributor.author | Tomas, A. | |
dc.contributor.author | Veenhof, R. | |
dc.contributor.buuauthor | Şahin, Özkan | |
dc.contributor.buuauthor | ŞAHİN, ÖZKAN | |
dc.contributor.department | Bursa Uludağ Üniversitesi/Fen Edebiyat Fakültesi | |
dc.contributor.researcherid | I-9715-2017 | |
dc.date.accessioned | 2024-08-13T11:03:10Z | |
dc.date.available | 2024-08-13T11:03:10Z | |
dc.date.issued | 2015-12-21 | |
dc.description | ||
dc.description.abstract | We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in similar to 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +/- 0.13 mm-sigma (longitudinal), 0.95 +/- 0.20 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8 mm x 8 mm x 1.2 mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (epsilon) at full width half maximum (R) inside the fiducial volume ranged from R = 14.6% (30 keV) to R = 4.6% (1.275 MeV).This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (beta beta 0 nu) in Xe-136, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R =1.4%root MeV/epsilon levels obtained in small sensors are discussed. | |
dc.description.sponsorship | European Research Council (ERC) 339787-NEXT -- 240054-TREX | |
dc.description.sponsorship | Spanish Government CSD2008-0037 (CUP) CSD2007-00042 (CPAN) FPA2008-03456 FPA2009-13697 | |
dc.description.sponsorship | Fundacao para a Ciencia e a Tecnologia (FCT) | |
dc.description.sponsorship | European Union (EU) PPTDC/FIS/103860/2008 | |
dc.description.sponsorship | United States Department of Energy (DOE) DE-AC02-05CH11231 | |
dc.identifier.doi | 10.1016/j.nima.2015.08.033 | |
dc.identifier.endpage | 24 | |
dc.identifier.issn | 0168-9002 | |
dc.identifier.startpage | 8 | |
dc.identifier.uri | https://doi.org/10.1016/j.nima.2015.08.033 | |
dc.identifier.uri | https://hdl.handle.net/11452/43978 | |
dc.identifier.volume | 804 | |
dc.identifier.wos | 000364133700002 | |
dc.indexed.wos | WOS.SCI | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.relation.journal | Nuclear Instruments & Methods In Physics Research Section A-accelerators Spectrometers Detectors And Associated Equipment | |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi | |
dc.subject | Trimethylamine | |
dc.subject | Fluctuations | |
dc.subject | Double-beta decay | |
dc.subject | Gamma and electron detection | |
dc.subject | Microbulk micromegas | |
dc.subject | Time projection chamber | |
dc.subject | High pressure xenon-trimehylamine | |
dc.subject | Penning-fluorescent mixtures | |
dc.subject | Science & technology | |
dc.subject | Technology | |
dc.subject | Physical sciences | |
dc.subject | Instruments & instrumentation | |
dc.subject | Nuclear science & technology | |
dc.subject | Physics, nuclear | |
dc.subject | Physics, particles & fields | |
dc.subject | Instruments & instrumentation | |
dc.subject | Nuclear science & technology | |
dc.subject | Physics | |
dc.title | Accurate γ and mev-electron track reconstruction with an ultra-low diffusion xenon/tma tpc at 10 atm | |
dc.type | Article | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | cd820bc7-96c0-4cc0-8d0a-54e5bcd5ecf4 | |
relation.isAuthorOfPublication.latestForDiscovery | cd820bc7-96c0-4cc0-8d0a-54e5bcd5ecf4 |