Publication:
Influence of window parameters on the thermal performance of office rooms in different climate zones of Turkey

dc.contributor.buuauthorALTUN, AYŞE FİDAN
dc.contributor.buuauthorKILIÇ, MUHSİN
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentMakina Mühendisliği Bölümü
dc.contributor.orcid0000-0001-7236-8398
dc.contributor.orcid0000-0003-2113-4510
dc.contributor.researcheridABB-9566-2020
dc.contributor.researcheridO-2253-2015
dc.date.accessioned2024-11-08T11:41:06Z
dc.date.available2024-11-08T11:41:06Z
dc.date.issued2019-03-01
dc.description.abstractWindow and faqade characteristics significantly influence the energy consumption of office buildings. This paper investigates the influence of window configuration on its energy performance regarding shading levels, orientation, geometrical characteristics, and thermo-physical properties. A series of simulations of two common type of office room models were conducted with changing parameters such as the window-to-wall ratio of the faqade, total solar energy transmittance value of the glazing, as well as shading levels regarding orientations. The energy simulations were performed using TRNSYS software for the climatic conditions of Istanbul, Ankara, Izmir, and Hakkari. It was found that appropriate selection of windows and shading devices regarding climatic conditions would lead to a significant reduction of the annual energy consumption and greenhouse gas emissions. The recommendations presented in this paper can be applied to any location around the world that has similar climatic conditions with the cities studied in this work.
dc.identifier.endpage243
dc.identifier.issn1309-0127
dc.identifier.issue1
dc.identifier.startpage226
dc.identifier.urihttps://hdl.handle.net/11452/47635
dc.identifier.volume9
dc.identifier.wos000473171100023
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherInt Journal Renewable Energy Research
dc.relation.journalInternational Journal Of Renewable Energy Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectEnergy-consumption
dc.subjectBuildings
dc.subjectOptimization
dc.subjectRegions
dc.subjectDesign
dc.subjectSize
dc.subjectSimulations
dc.subjectOrientation
dc.subjectThickness
dc.subjectBalance
dc.subjectWindow
dc.subjectThermal performance
dc.subjectShading
dc.subjectTotal solar energy transmittance
dc.subjectHeating
dc.subjectCooling
dc.subjectScience & technology
dc.subjectTechnology
dc.subjectEnergy & fuels
dc.titleInfluence of window parameters on the thermal performance of office rooms in different climate zones of Turkey
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Makina Mühendisliği Bölümü
relation.isAuthorOfPublication5e35ca17-773e-44bc-be88-55a02ff60959