Publication: Comparison of central corneal thickness estimated by an ultrasonic pachymeter and non-contact specular microscopy
dc.contributor.author | Çevik, Sadık Görkem | |
dc.contributor.author | Duman, Rahmi | |
dc.contributor.author | Çevik, Mediha Tok | |
dc.contributor.author | Kıvanç, Serta Argun | |
dc.contributor.author | Akova-Budak, Berna | |
dc.contributor.author | Perente, İrfan | |
dc.contributor.author | Duman, Reşat | |
dc.contributor.buuauthor | Kıvanç, Serta Argun | |
dc.contributor.buuauthor | Akova-Budak, Berna | |
dc.contributor.department | Tıp Fakültesi | |
dc.contributor.department | Göz Hastalıkları Ana Bilim Dalı | |
dc.contributor.orcid | 0000-0003-0995-5260 | |
dc.contributor.researcherid | AAH-6518-2021 | |
dc.contributor.researcherid | ABE-3033-2020 | |
dc.date.accessioned | 2024-08-13T11:28:18Z | |
dc.date.available | 2024-08-13T11:28:18Z | |
dc.date.issued | 2016-05-20 | |
dc.description.abstract | Purpose: To compare central corneal thickness (CCT) measurements of healthy individuals obtained with ultrasonic pachymetry (UP) and non-contact specular microscopy (NCSM).Method: In total, 148 eyes of 74 subjects with no ocular or systemic diseases were included in the study. Central corneal thickness measurements of all patients performed with UP and NCCM were compared.Results: A total of 74 subjects (38 females) were included in this study. The mean age was 45.2 +/- 18.4 (range 12-85) years. The mean central corneal thickness of all 148 eyes was 546.9 +/- 40 mu m with UP and 510.8 +/- 42 mu m with NCSM. The mean central corneal thickness measured with NCSM was 35 mu m thinner than that measured with UP (p < 0.001). A high degree of agreement was found between the two methods (r = 0.942, p < 0.001).Conclusions: Our results suggest that NCSM measures thinner corneas than UP and that the correction formula we identified should be applied when comparing between these two devices. | |
dc.identifier.doi | 10.5935/0004-2749.20160089 | |
dc.identifier.endpage | 314 | |
dc.identifier.issn | 0004-2749 | |
dc.identifier.issue | 5 | |
dc.identifier.scopus | 2-s2.0-85009812482 | |
dc.identifier.startpage | 312 | |
dc.identifier.uri | https://doi.org/10.5935/0004-2749.20160089 | |
dc.identifier.uri | https://www.scielo.br/j/abo/a/5swBLrYjRTkXsqXLBZwWtzs/?lang=en&format=pdf | |
dc.identifier.uri | https://hdl.handle.net/11452/43983 | |
dc.identifier.volume | 79 | |
dc.identifier.wos | 000391431500008 | |
dc.indexed.wos | WOS.SCI | |
dc.language.iso | en | |
dc.publisher | Consel Brasil Oftalmologia | |
dc.relation.journal | Arquivos Brasileiros De Oftalmologia | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Optical coherence tomography | |
dc.subject | Repeatability | |
dc.subject | Pentacam | |
dc.subject | Reproducibility | |
dc.subject | Orbscan | |
dc.subject | Cornea/pathology | |
dc.subject | Corneal pachymetry | |
dc.subject | Microscopy/methods | |
dc.subject | Cornea/anatomy & histology | |
dc.subject | Comparative study | |
dc.subject | Ophthalmology | |
dc.title | Comparison of central corneal thickness estimated by an ultrasonic pachymeter and non-contact specular microscopy | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.contributor.department | Tıp Fakültesi/Göz Hastalıkları Ana Bilim Dalı | |
local.indexed.at | WOS | |
local.indexed.at | Scopus |
Files
Original bundle
1 - 1 of 1