Simultaneous determination of metronidazole and miconazole in pharmaceutical dosage forms by RP-HPLC
No Thumbnail Available
Date
2002-11
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Science
Abstract
A reversed-phase high performance liquid chromatography (RP-HPLC) method with UV detection is described for the simultaneous determination of metronidazole and miconazole in pharmaceutical dosage forms. Chromatography was carried out on a Cl 8 reversed-phase column, using a mixture of methanol-water (40 + 60, v/v) as a mobile phase, at a flow rate of 1.0 ml min(-1). Sulfamethoxazole was used as an internal standard and detection was performed using a diode array detector at 254 nm. The method produced linear responses in the concentration ranges 10-70 and 1-20 mug ml(-1) with detection limits 0.33 and 0.27 mug ml(-1) for metronidazole and micanozole, respectively. This procedure was found to be convenient and reproducible for analysis of these drugs in ovule dosage forms. (C) 2002 Editions scientifiques et medicales Elsevier SAS. All rights reserved.
Description
Keywords
Pharmaceutical dosage forms, Pharmacology & pharmacy, Reversed-phase high performance liquid chromatography, Amperometric detection, Metronidazole and miconazole, Performance liquid-chromatography, Derivatıve spectrophotometry, Creams, Plasma, Metabolites, Extraction, Nitrate, Drugs
Citation
Akay, C. vd. (2002). "Simultaneous determination of metronidazole and miconazole in pharmaceutical dosage forms by RP-HPLC". Farmaco, 57(11), 953-957.